[摘要]天津国际贸易中心A座公寓楼高235m,采用钢框架-支撑核心筒体系,是一座补强重建、纯钢结构的超高层公寓楼。依据天津小白楼地区风洞试验数据,采用ETABS软件,对在避难层加设套索式安装的液体粘滞阻尼器的结构进行舒适度计算及分析,并对阻尼器的参数、安装位置和数量等内容进行优化,从而实现结构的安全性与舒适性。该方法不仅替代了在传统结构中逐层或隔层均匀布置斜撑或人字撑阻尼器的方法,也替代了抗风减振常用的TMD系统,有效减小了A座公寓楼在脉动风压作用下的楼层加速度,满足高钢规对超高层公寓楼舒适度的有关规定;设置阻尼器后,结构在地震作用下表现出较好的抗震性能,一定程度上提高了结构的抗震耗能能力。
[关键词]超高层钢结构; 建筑舒适度; 液体粘滞阻尼器; 加速度; 套索
中图分类号:TU352.1文献标识码:A文章编号:1002-848X(2013)13-0031-05
 
Comfort design for building A of Tianjin International Trade Center
Han Wei1, Lv Kevin1, You Xusheng1, Peng Cheng2, Chen Yongqi2
 (1 Capitaland (China) Investment Co., Ltd., Beijing 100007, China; 2 Beijing Qitai Shock Control and Scientific Development Co., Ltd., Beijing 100037, China)
 
Abstract: The building A of Tianjin International Trade Center, rising to 235m, is a super high-rise apartment building of steel frame-core brace structure. According to the time-history data from the wind tunnel test for the Xiaobailou area of Tianjin, ETABS software was used to calculate and analyze the comfort of the structure with the placing toggle-braced fluid viscous dampers located in the refuge stories. A series of contents of the dampers like parameters, installation locations as well as quantities were optimized, so as to meet the requirements of safety and comfort of the structure simultaneously. The method has replaced the assigning not only diagonal or chevron damper installation, but also TMD system which is usually been applied for wind resistance. It has effectively reduced the floor acceleration of the structure in fluctuating wind, so that the structure has satisfied the relevant provisions of comfort of super high-rise apartment buildings in codes. The structure was observed to behave a good anti-seismic performance by setting dampers, and its energy dissipation capacity was enhanced.
Keywords: super high-rise steel structure; building comfort; fluid viscous damper; acceleration; toggle
作者简介:韩维,硕士,英国皇家特许工程师,Email: Han.wei@capitaland.com.cn。
 
参考文献
[1]JGJ 99—98 高层民用建筑钢结构技术规程[S].北京:中国建筑工业出版社,1998.
[2]彭程, 陈永祁. 液体粘滞阻尼器和调谐质量阻尼器(TMD)在高层结构上的抗风效果对比[J]. 工程抗震与加固改造,2013,35(3):98-105.
[3]HUANG H. Efficiency of the motion amplification device with viscous dampers and its application in high-rise building [J]. Earthquake Engineering and Engineering Vibration, 2009,8(4):521-536.
[4]陈永祁. 一种防震的粘滞阻尼器连接系统:中国,ZL 2012 2 0375511.8[P]. 2013-02-13.
[5]周云. 粘滞阻尼减震结构设计[M]. 武汉:武汉理工大学出版社,2006:212.
[6]FEMA 368 NEHRP recommended provisions for seismic regulations for new buildings and other structures provisions[S]. 2000 ed. Washington, D.C.: Building Seismic Safety Council, 2001.
[7]GB 50011—2010 建筑抗震设计规范[S].北京:中国建筑工业出版社,2010:159,316.
[8]CONSTANTINOU M. San Diego Courthouse damper preliminary test reprot [R]. New York: 2012.
[9]马良喆,陈永祁.金属密封无摩擦阻尼器介绍及工程应用[J]. 工程抗震与加固改造,2009,31(5):46-51.
下载地址

    你还没注册?或者没有登录?这篇论文要求至少是本站的注册会员才能阅读!

    如果你还没注册,请赶紧点此注册吧!

    如果你已经注册但还没登录,请赶紧点此登录吧!