您现在的位置:建筑结构>> 期 刊>> 2013年>> 第11期>>正文内容
钢管壁开洞组合柱试件轴心受压性能试验研究
万怡秀1,李宁波2,吴昭华1,刘翔1,郑同亮1,钱稼茹2
摘 要

 

万怡秀1,李宁波2,吴昭华1,刘翔1,郑同亮1,钱稼茹2
 (1 北京富力城房地产开发有限公司, 北京 1000222 清华大学土木工程安全与耐久教育部重点实验室, 北京 100084)
[摘要]为研究圆钢管壁开洞率对钢筋混凝土梁钢管混凝土组合柱节点核心区轴心受压性能的影响,进行了14个钢管壁开洞和4个钢管壁不开洞的钢管混凝土组合柱试件的轴心受压试验。试验结果表明:钢管壁开洞率不大于50%时,试件的轴心受压承载力没有显著降低;钢管壁开洞率为50%且壁厚由8mm增大到12mm14mm时,试件轴心受压承载力有较大提高;设置加劲板加强钢管壁洞口四周的试件,轴压力纵向应变曲线在峰值点后下降平缓,试件的塑性变形能力明显提高。考虑钢管对混凝土的约束作用时,试件轴心受压承载力计算值与试验值符合较好;不考虑圆钢管对混凝土约束作用时,试件的轴心受压承载力计算值小于试验值较多。建议计算试件轴心受压承载力应考虑钢管对混凝土的约束作用。
[关键词]钢管混凝土组合柱; 钢管壁开洞; 轴心受压性能; 试验研究
中图分类号:TU398文献标识码:A文章编号:1002848X(2013)11001207
Experimental study on axial compressive behavior of composite column specimens with openings on steel tube wall
Wan Yixiu1, Li Ningbo2, Wu Zhaohua1, Liu Xiang1, Zheng Tongliang1, Qian Jiaru2
 (1 Beijing R&F Properties Development Co., Ltd., Beijing 100022, China; 2 Key Laboratory of Civil Engineering Safety and Durability of China Education Ministry, Tsinghua University, Beijing 100084, China)
Abstract:To study the influence of opening ratio of the steel tube wall on the axial compressive behavior of core area of RC beam and concrete filled steel tube composite column joint, quasistatic tests on 18 composite column specimens were conducted. Among the 18 specimens, there were 14 specimens with large openings and 4 specimens without openings on the steel tube wall. Results indicate that the openings have little influence on the axial compressive strength of the specimens when the opening ratio is less than 50%. For the specimens with the opening ratio of 50%, the axial compressive strength increases significantly when the thickness of steel tube wall increases from 8mm to 12mm or 14mm. The axial compressive loadlongitudinal strain curves of the specimens drop slowly and the plastic deformation capacity enhances greatly, when the steel tube is strengthened by stiffeners along the perimeter of openings. Taking into consideration of the confinement effect of steel tube on the core concrete, the calculated axial compressive strength of specimens is in good agreement with the test results, but it is much smaller than that of the test results without taking into consideration of the confinement effect of steel tube on the core concrete. Taking into consideration of the confinement effect of steel tube on the core concrete is recommended in the calculation of axial compressive strength of specimens.
Keywords:concrete filled steel tube composite column; opening hole on steel tube wall; axial compressive behavior; experimental study
作者简介:
万怡秀,一级注册结构工程师,设计研发中心总结构师,Emailwanyixiu@qq.con
参考文献
1CECS 188:2005 钢管混凝土叠合柱结构技术规程[S. 北京:中国计划出版社,2005.
2]叶列平.混凝土结构设计[M. 北京:中国建筑工业出版社,2012.
3GB 500102010 混凝土结构设计规范[S. 北京:中国建筑工业出版社,2011.
4JGJ 32010 高层建筑混凝土结构技术规程[S. 北京:中国建筑工业出版社,2011.
5]钱稼茹,程丽荣,周栋梁.普通箍筋约束混凝土柱的中心受压性能[J.清华大学学报:自然科学版, 2007, 42(10):13691372.