- 摘 要
-
(1 深圳市电子院技术开发有限公司,518031,2 中国石油大学,北京102249)
[提要]深圳大梅沙度假酒店是平面和竖向均不规则的复杂高层钢结构。分别采用振动台试验和动力弹塑性时程分析方法对该结构方案进行了验证和分析,两种方法结果一致,证明该结构能够满足7度抗震设防要求。相比之下,基于材料本构关系的动力弹塑性时程分析方法具有可行性强、结果完备、成本低等优势。
[关键词]振动台试验;动力弹塑性;时程分析;ABAQUS
Analysis on a Highrise Steelframed Structure with Truss Transfer Story/Wang Chuanjia1, Chen Zhiqiang1, Wang Qingyang1,2, Biao Fangjun1,Yan Xiaoming1, Zhang Jin2(1 SEDI Technology Development Co., Ltd., Shenzhen 518031,China; 2 China University of Petroleum, Beijing 102249,China)
Abstract:A hotel in Shenzhen is a highrise steelframed structure with irregularity both in horizontal and vertical direction.The shaking table test andelasticplastic time history analysis method are used to verify and analyze the seismic behavior of the structure. The same results prove that it can meet the requirement of the aseismic code. Relatively, elasticplastic time history analysis method based on constitutive equations of materials is more feasible, comprehensive and economical.
Keywords:shaking table test; elasticplastic; time history analysis; ABAQUS