- 摘 要
-
李 辉,杨红卫,张 玲,马 进
(吉林省阳光建设工程咨询有限公司,吉林130022)[摘要] 汶川地震后,《建筑工程抗震设防分类标准》(GB50223-2004)进行了修订,将中小学校舍的抗震类别由原来的丙类提高到乙类。在这种背景下,通过对吉林省内部分中小学校舍近百栋房屋进行抗震排查鉴定工作,总结实践经验,查阅相关技术标准,认真研究规范条款,得出便于使用与理解掌握的抗震鉴定方法,对后续的中小学校舍抗震鉴定及加固改造工程具有实际意义。
[关键词] 砌体结构;抗震鉴定;分类分级鉴定;工程实例Illustrations of earthquake-resistant evaluation for masonry structure of primary and secondary schools
Li Hui, Yang Hongwei, Zhang Ling, Ma Jin
( Jilin Sunny Construction Engineering Consultation Co., Ltd., Jilin 130022, China)Abstract: Afier WenChuan Earthquake, Code for classilz'cation of seismic protection of buildings( GB20223-2004) was revised and anti-seismic classification of buildings of primary and secondary schools was upgraded from Group C to Group B.According to this background, hundreds of buildings of primary and secondary schools in Jilin Province were checked by earthquake-resistant evaluation and then some simplified earthquake-resistant evaluation methods based on relative technical standards and regulations are summed up. It was sure that those methods are absolutely significant to later earthquake-resistant evaluation for primary and secondary schools' buildings as well as reinforcement engineermg and modification works.
Keywords: masonry structure; earthquake-resistant evaluation; classification and determination; case history.