您现在的位置:建筑结构>> 期 刊>> 2010年>> 增刊02期>>正文内容
上海某办公楼的加层设计
张守峰
摘 要

    张守峰
    (中国建筑设计研究院上海分院,上海200120)

[摘要] 某工程原建筑使用功能为粮库,结构形式为板柱结构,业主要求改变使用功能为办公,并且在不加固基础的前提下适当加层。通过对原建筑进行结构安全性鉴定和抗震鉴定,根据相应的《鉴定报告》提出三个可行的结构加层设计方案,并将三个设计方案进行优化对比,最后选用板柱-抗震墙结构作为改造加层的实施方案。
[关键词] 板柱结构;抗震鉴定;板柱-抗震墙结构

    Design of adding extra-floor to an existing office building in Shanghai
    Zhang Shoufeng
    ( China Architecture design&Research Group Shanghai Branch, Shanghai 200120, China)

Abstract: The four-floor building with plate-column structure, the original function of which is grain depot, needs to change for office and add extra-floor advisably without strengthening the foundation of the building, at the request of the landlord. Therefore, the safety and earthquake-resistant appraisal had been finished. Based on the appraisal report, three feasible plans of the adding extra-floor were put forward. Through contrasting the plans, the plate-column and shear wall structure is chosen for the optimum plan of the renovation.
Keywords: plate-column structure; earthquake-resistant appraisal; plate-column and shear wall structure