- 摘 要
-
(1 湖南大学土木工程学院,长沙 410082;2 深圳市建筑设计研究总院有限公司,深圳 518031;3 长沙理工大学土木与建筑学院,长沙 410076)
[摘要]泊富国际广场公寓楼高度接近规范对B级高度建筑最大容许值。原设计方案由于塔楼偏置、纵横向抗侧刚度相差较大以及竖向抗侧刚度突变等原因,导致结构抗震性能无法满足设计要求。利用MIDAS/Gen平台对结构进行了静力非线性计算与评价,并依据分析结论对结构方案进行局部调整与改进。通过对比分析发现,改进后的结构方案在抗震性能上获得了明显改善,结构构件预期性能达到目标水准。
[关键词]超限高层建筑;框架-剪力墙结构;静力弹塑性分析;抗震性能
中图分类号:TU311-3文献标识码:A文章编号:1002-848X(2012)03-0015-05
Seismic performance and structural scheme improvement oftall apartment building of Bofu International Plaza
Chen Kui1,Li Hui2,Liu Zhefeng3,Shen Pusheng1(1 College of Civil Engineering, Hunan University, Changsha 410082, China; 2 Shenzhen General Institute of Architectural Design and Research, Shenzhen 518031, China;3 School of Civil Engineering and Architecture,Changsha University of Science & Technology,Changsha 410076, China)
Abstract:The height of the tall apartment building of Bofu International Plaza is closed to the maximum allowed height of the specification for Class B building in the code. Due to relatively large offset at the bottom of the tower podium, a significant difference between longitudinal and transverse drift stiffness and the mutation of the vertical lateral stiffness, the structural anti-seismic performance could not meet the design requirements. A nonlinear static calculation and evaluation on the structure were done utilizing MIDAS/Gen program. According to the results, some adjustments and improvements of the structural scheme were proposed. Through the comparative analysis, the seimic performance of the modified structural scheme is better and the prospective of structural components is supposed to reach the expected level.
Keywords:tall building beyond the code-specification; frame-wall structure; static pushover analysis; seismic performance
作者简介:陈逵,博士研究生,Email:richardck@126.com。
参考文献
[1]王昌兴.MIDAS/Gen 应用实例教程及疑难解答[M]. 北京:中国建筑工业出版社,2010.
[2]缪志伟,叶列平.框架-核心筒高层混合结构抗震性能评价及破坏模式分析[J].建筑结构,2009,39(4):1-6.
[3]魏琏,王森,王志远,等.静力弹塑性分析方法的修正及其在抗震设计中的应用[J].建筑结构,2006,36(8):47-52.
[4]白国良,孙海水.基于梁柱线刚度比的型钢混凝土柱钢梁混合框架静力弹塑性分析[J].建筑结构,2009,39(4):7-9.
[5]ATC40-Seismic evaluation and retrofit of concrete buildings[S]. Applied Technology Council,1996.
[6]FEMA273,FEMA356. NEHRP guidelines for the seismic rehabilitation of buildings[S]. Washington D C: Federal Emergency Management Agency, 1996.
[7]沈蒲生.高层建筑结构疑难释义[M].北京:中国建筑工业出版社,2003