您现在的位置:建筑结构>> 期 刊>> 2022年>> 第23期>>正文内容
低层双面叠合夹心保温剪力墙结构动力弹塑性分析研究
吴学淑1,2, 李进军1,2, 王平山1,2, 纵 斌1,2
摘 要

(1 华东建筑设计研究院有限公司, 上海 200011;2 上海装配式建筑技术集成工程技术研究中心, 上海 200011)

摘要: 基于足尺模型振动台试验,对低层双面叠合夹心保温剪力墙结构进行动力弹塑性分析,并对数值计算结果和振动台试验结果进行对比,结果表明,有限元计算的结构响应及构件损伤情况基本和振动台试验结果相吻合,7度罕遇地震时该结构基本处于弹性状态,8 度罕遇地震时构件损伤发展,9 度罕遇地震时结构进入弹塑性状态,但变形满足大震不倒的要求。 对有外叶墙模型和无外叶墙模型的动力弹塑性计算结果进行对比,随着输入地震波峰值加速度增大,两者结构响应发展趋势基本一致,无外叶墙模型的结构位移响应略大于有外叶墙模型,两者构件损伤位置和损伤发展趋势基本一致,无外叶墙模型墙体损伤程度略大。 分析结果表明,在结构弹塑性状态下,外叶墙和桁架筋对结构抗震能力具有一定贡献,降低结构在地震作用下的损伤。

关键词: 双面叠合夹心保温剪力墙结构; 有外叶墙模型; 无外叶墙模型; 罕遇地震; 动力弹塑性分析

中图分类号:TU375 ,TU317+. 1 文献标志码:A 文章编号:1002-848X(2022)23-0019-07

DOI:10. 19701 / j. jzjg. HJZL2204

Study on dynamic elasto-plastic analysis of low-rise double-faced superimposed sandwich insulation shear wall structure

WU Xueshu1,2, LI Jinjun1,2, WANG Pingshan1,2, ZONG Bin1,2

(1 East China Architectural Design and Research Institute Co. , Ltd. , Shanghai 200011, China; 2 Shanghai EngineeringResearch Center of Assembly Building Technology Integration, Shanghai 200011, China)

Abstract: Based on the full-scale shaking table test, the dynamic elasto-plastic analysis of the low-rise double-facedsuperimposed sandwich insulation shear wall structure was carried out, and the numerical calculation results with theshaking table test results were compared. The results show that the structural response and damage calculated by finiteelement analysis are almost consistent with the results of the shaking table test. The structure is basically in an elastic stateduring the 7 degree rare earthquake, the component damage develops during the 8 degree rare earthquake, and the structureenters an elastic-plastic state during the 9 degree rare earthquake, but it’ s deformations meet the requirements of nocollapse under rare earthquake. The dynamic elastic-plastic calculation results of the model with and without outerprefabricated wall were compared. With the increase of the peak acceleration of the input seismic wave, the developmenttrend of the structural response of the two models is basically consistent. The displacement response of the model withoutouter prefabricated wall is slightly greater than that of the model with outer prefabricated wall. The damage location anddamage development trend of the two models are basically consistent, and the damage degree of the model without outerprefabricated wall is slightly greater. The analysis results show that under the elastic-plastic state of the structure, the outerprefabricated wall and truss reinforcement connectors have contribution to the seismic capacity of the structure and reducesthe damage of the structure under seismic load.

Keywords:low-rise double-faced superimposed sandwich insulation shear wall structure;model with prefabricated wall;model without prefabricated wall; rare earthquake dynamic elasto-plastic analysis

∗国家重点研发计划资助(2018YFD1100903)。

第一作者:吴学淑,博士,高级工程师,一级注册结构工程师,主要从事装配式结构研究,Email:xueshu_wu@ 163. com。

[引用本文] 吴学淑,李进军,王平山,等. 低层双面叠合夹心保温剪力墙结构动力弹塑性分析研究[ J] . 建筑结构,2022,52( 23) :19-25. WU Xueshu,LI Jinjun,WANG Pingshan,et al. Study on dynamic elasto-plastic analysis oflow-rise double-faced superimposed sandwich insulation shear wall structure [ J] . Building Structure, 2022, 52 ( 23) :19-25.

下载地址

    你还没注册?或者没有登录?这篇论文要求至少是本站的注册会员才能阅读!

    如果你还没注册,请赶紧点此注册吧!

    如果你已经注册但还没登录,请赶紧点此登录吧!