龙光总部中心结构设计研究
彭肇才, 李志德, 张 聪, 李 雄, 李永安, 黄志勇
摘 要

(广东现代建筑设计与顾问有限公司, 深圳 518010)

摘要: 龙光总部中心为两栋“钢管混凝土叠合柱框架-核心筒”结构塔楼及钢桁架在高位形成的多重复杂连体结构. 详细介绍了该结构的基础设计、结构体系的选型,从结构整体性能指标、结构抗震性能目标、结构最大层间位移角、剪重比等方面全面阐述了结构的设计策略,并对结构进行连体多塔与单塔包络设计. 结果表明,结构各项指标均满足规范要求,结构具有足够的安全冗余度.

关键词: 框架-核心筒结构; 连体结构; 钢管混凝土叠合柱; 模态分析; 抗震性能目标; 包络设计

中图分类号:TU973 文献标志码:A 文章编号:1002-848X(2023)04-0063-05

DOI:10. 19701 / j. jzjg. 20201414

Research on structural design of Logan Headquarters Center

PENG Zhaocai, LI Zhide, ZHANG Cong, LI Xiong, LI Yongan, HUANG Zhiyong

(Guangdong Modern Architectural Design & Consulting Co. , Ltd. , Shenzhen 518010, China)

Abstract: Logan Headquarters Center is composed of two " concrete-filled steel tube composite column frame-core tube"structural towers and steel trusses, which form multiple complex connected structure at high positions. The basic design ofthe structure and the selection of the structural system were introduced in detail. The design strategy of the structure wasdescribed comprehensively from the overall performance index of the structure, structural seismic performance target,maximum inter story displacement angle of the structure, shear weight ratio, etc. , and envelope design for the structure ofmultiple connected towers and single tower was carried out. The results show that all indicators of the structure meet therequirements of the specification, and the structure has sufficient safety redundancy.

Keywords:frame-core tube structure; conjoined structure; concrete-filled steel tube composite column; modal analysis;seismic performance objective; envelope design

第一作者:彭肇才,学士,教授级高级工程师,一级注册结构工程师,主要从事结构设计研究工作,Email: 82232925@ qq. com.

[引用本文] 彭肇才,李志德,张聪,等. 龙光总部中心结构设计研究[J]. 建筑结构,2023,53(4):63-67,113. PENGZhaocai,LI Zhide, ZHANG Cong, et al. Research on structural design of Logan Headquarters Center [ J]. BuildingStructure,2023,53(4):63-67,113.