您现在的位置:建筑结构>> 期 刊>> 2018年>> 第09期>>正文内容
岩溶地区复合地基静压PHC管桩应用分析*
王维俊,张立,李伟科,韩建强,王伟江
摘 要

(广州市设计院, 广州 510620)

[摘要]通过对岩溶地区某高层住宅塔楼基础方案的比选,论述了静压PHC管桩在岩溶地区CM复合地基的适用性,验证了在岩土面较平整的岩溶地区,静压PHC管桩复合地基具有较好的经济性和环保性。同时,提出桩底溶洞注浆加固的方案。依据规范对CM复合地基的承载力和沉降进行了计算。计算结果表明,CM复合地基承载力与沉降满足规范要求。在此基础上,开展现场载荷试验并采用软件YJK对CM复合地基进行三维有限元分析。现场试验和有限元分析验证了静压PHC管桩复合地基设计的合理性,保证了基础设计的安全性。

[关键词]岩溶地区; 复合地基; 基础方案选型; 静压PHC管桩; 溶洞注浆加固

中图分类号:TU472文献标识码:A文章编号:1002-848X(2018)09-0112-04

 

Application analysis of static pressure PHC pipe pile in composite foundation in karst district

Wang Weijun, Zhang Li, Li Weike, Han Jianqiang, Wang Weijiang

(Guangzhou Design Institute, Guangzhou 510620, China)

Abstract:Based on the comparison and selection of the foundation scheme of a high-rise building in karst area, the adaptability of static pressure PHC pipe pile used in the composite foundation in karst area was discussed. The composite foundation with static pressure PHC pipe pile was proved to be economic and environment protection in a relatively flat karst area. At the same time, the scheme of karst cave grouting reinforcement at the bottom of the pile was put forward. According to the code, the bearing capacity and settlement of the CM composite foundation were calculated. The results show that the bearing capacity and settlement of the CM composite foundation can meet the code requirements. And on this basis, the in-situ plate load test and YJK software were used to analyze the CM composite foundation using three-dimensional finite element method. The test results and finite element analysis verify the rationality of the composite foundation design with static pressure PHC pipe pile, and ensure the safety of the foundation design.

Keywords:karst district; composite foundation; foundation scheme selection; static pressure PHC pipe pile; karst cave grouting reinforcement

 

*国家自然科学基金资助(51608138)。

 

作者简介:王维俊,硕士,高级工程师,一级注册结构工程师,Email:wangweijun@gzdi.com。