您现在的位置:建筑结构>> 期 刊>> 2010年>> 第11期>>正文内容
宿迁某高层办公楼基础隔震设计方法
杜东升,王曙光,刘伟庆,孙臻
摘 要

 

(南京工业大学土木工程学院,南京 210009

[摘要]某办公楼位于地震高烈度区江苏省宿迁市,为了提高其抗震性能采用了基础隔震技术。由于我国规范对地震高烈度区建造高层隔震建筑还没有明确的设计依据,文中将基于性能的设计方法应用于该建筑的基础隔震设计中。为满足设定的抗震性能目标,隔震层采用了组合隔震形式,由纯天然橡胶隔震支座、铅芯橡胶隔震支座和粘滞阻尼器组成。分析表明,各类隔震器充分发挥了其设计性能,隔震层在罕遇地震下工作状态稳定,上部结构的地震响应有了明显的降低。

[关键词]高层建筑;基础隔震;基于性能设计; 组合隔震

Design of base isolation for a high-rise office building in Suqian

Du Dongsheng, Wang Shuguang, Liu Weiqing, Sun Zhen

College of Civil Engineering, Nanjing University of Technology, Nanjing 210009, China

Abstract:The design method of hybrid base isolation was applied to an office building in Suqian, which is a region of high earthquake intensity. In China, there is no specific design basis for isolated technique application in high-rise buildings. Performance-based seismic design method was applied to this building. In order to reach the setting target of seismic performance, combination form was adopted in isolation floor composed of rubber bearing and viscous damping. Analysis results prove the stabilized operating state of isolation floor, the obvious decreasing in seismic response of upper structure, as well as the satisfaction for the design requirements.

Keywords:high-rise building; base isolation; performance-based design method; hybrid isolation

国家自然科学基金资助项目(50908115,50608039),国家自然科学基金重大研究计划(90815017),南京工业大学青年教师学术基金。

作者简介:杜东升,博士,副教授,Email:ddshy@163.com