- 摘 要
-
(奥雅纳工程顾问, 上海 200031)
[摘要]针对不同形式的超高层巨型钢管混凝土柱-钢梁新型刚接连接节点,进行了静力加载试验和滞回试验,对试验结果与有限元数值模拟分析结果进行对比分析。结果表明,T形加劲肋能有效传递钢梁内力,能达到“强柱弱梁、强节点弱构件”的设计要求,是一种合理有效的节点构造措施。
[关键词]钢管混凝土柱; 内加劲环; 竖向加劲肋; 有限元方法; 静力试验; 抗震性能试验
中图分类号:TU318-2文献标识码:A文章编号:1002-848X(2017)14-0069-05
Experiment on new rigid joint of mega concrete filled steel tubular column and steel beam in super high-rise building
Zhu Ligang
(Arup, Shanghai 200031, China)
Abstract:Static loading tests and cyclic loading tests were conducted on different forms of new type of rigid joints in mega concrete filled steel tubular column and steel beam in super high-rise building. The finite element numerical simulation analysis results were compared with the experimental results. The results show that the T-shaped stiffener can effectively transmit the internal force of the steel beam, and can meet the design requirements of "strong column, weak beam and strong joint". It is a reasonable and effective joint construction measures.
Keywords:concrete filled steel tubular column; internal stiffening ring; vertical stiffener; FEM; static test; seismic performance test
作者简介:朱立刚,高级工程师,一级注册结构工程师,副总工程师,Email:Li-Gang.Zhu@arup.com。