- 摘 要
-
(1 华北理工大学建筑工程学院, 唐山 063009; 2 河北省地震工程研究中心, 唐山 063009)
[摘要]通过对现浇钢筋混凝土框架节点及不同预应力下附加角钢的预制装配框架节点进行低周反复荷载作用下的试验,研究梁柱节点的破坏过程、滞回曲线、变形性能等抗震性能。试验结果表明,相比现浇钢筋混凝土框架节点,附加角钢的预制装配框架节点破坏程度轻,且有很好的变形恢复能力,残余变形小,对抗震有利。
[关键词]预制装配框架结构; 节点; 角钢; 抗震性能
中图分类号:TV334, TU375文献标识码:A文章编号:1002-848X(2017)10-0071-04
Experimental study on effect of prestress on prefabricated frame joint with additional angle steel
Han Jianqiang1,2, Qi Feng1, Liu Yang1, Wang Yinhui1
(1 College of Civil and Architectural Engineering, North China University of Science and Technology, Tangshan 063009, China; 2 Earthquake Engineering Research Center of Hebei Province, Tangshan 063009, China)
Abstract:Through low cyclic loading tests of cast-in-place reinforced concrete frame joints and prefabricated frame joints with additional angle steel under different prestress, seismic performances of the beam-column joints were studied including failure process, hysteretic curve, and deformation properties and so on. Experimental results show that compared with cast-in-place reinforced concrete frame joints, prefabricated frame joints with additional angle steel has slighter damage, and there is a good energy dissipation capacity and small residual deformation, which is beneficial to seismic resistance.
Keywords:prefabricated frame structure; joint; angle steel; seismic performance
*国家自然科学基金项目资助(51208171),河北省科技支撑计划项目(13273809),河北省高等学校科学技术研究项目(ZD2014021)。
作者简介:韩建强,博士,副教授,硕士生导师,Email: tshjq@139.com。