- 摘 要
-
(广州瀚华建筑设计有限公司, 广州 510655)
[摘要]顺德绿地商业中心项目5#楼总高度229.6m,采用了框架-核心筒结构体系。分析了结构的超限情况并确定了抗震性能目标,采用了基于性能的抗震设计方法,对结构进行了小震弹性、中震等效弹性计算及大震下的弹塑性时程分析及转换桁架节点的有限元分析。以上分析可保证结构实现预先设定的抗震性能目标。
[关键词]超限高层建筑; 抗震性能设计; 弹塑性时程分析; 转换桁架
中图分类号: TU318 文献标识码: A文章编号: 1002-848X(2016)S2-0215-06
Perform-based seismic analysis and design on the 5# tower of
the Greenland Business Center in Shunde City
Sun Liang, Qiu Junwei
(Guangzhou Hanhua Architects+Engineers Co., Ltd., Guangzhou 510655, China)
Abstract: The 5# tower of the Greenland Business Center in Shunde City is 229.6m-height with RC frame-core structure system. The seismic performance objectives are determined. Performances of the structure were verified based on bearing capacity and deformation under different levels, including elastic analysis under frequent earthquake, unyielding analysis under intermediate earthquake, the elastic-plastic time-history analysis under rare earthquake. Key joints of the conversion truss are researched by finite element analysis. The above analysis is to accomplish the expected seismic performance objectives.
Keywords: out-of-code high-rise structure; perform-based seismic design; elastic-plastic time-history analysis; conversion truss
作者简介: 孙亮,硕士,高级工程师,一级注册结构工程师,注册土木工程师(岩土),Email:sunliang@gzhanhua.com。