钢筋混凝土受弯剪扭构件的最小配筋率
- 摘 要
-
(1 南昌大学建筑工程学院,南昌 330029; 2 中国对外建设工程总公司,北京 100048)[摘要]根据适用于弯剪扭构件最小配筋率的界限条件,推导得出受扭钢筋最小配筋率的计算表达式。在一般房屋结构构件常用范围内,将计算结果与我国《混凝土结构设计规范》(GB50010—2002)的规定分析对比,并提出修改该规范有关条文的建议。[关键词]弯剪扭构件;纯扭构件;受扭纵向钢筋最小配筋率Minimum reinforcement ratio of reinforced concrete torsion-bending-shear membersWu Weixiu1, Liu Shengpeng2, Yu Jinhui1, Lu Xiaozhu1 (1 School of Architecture Engineering, Nanchang University, Nanchang 330029, China;2 China Construction International Incorporated, Beijing 100048, China)Abstract:Based on the limits situation of the minimum reinforcement ratio of reinforced concrete torsion-bending-shear members, the formulas for the minimum ratio of the torsion stirrup and the longitudinal steel of members were obtained. The results of the formulas were contrasted with Code for Design of Concrete Structures (GB50010—2002) within the range of common used building structural members. The proposal concerning modified formula of this code was presented.Keywords:torsion-bending-shear members; pure torsion member; minimum ratio of longitudinal steel*南昌大学校基金课题(Z03307)。作者简介:伍卫秀,硕士,副教授,Email:wuweixiu@gmail.cn。参考文献[1]GB50010—2002 混凝土结构设计规范[S].北京:中国建筑工业出版社,2002.[2]何高勖,虞锦晖.钢筋混凝土矩形截面受扭构件的最小配筋率[J].建筑结构,1994,24(10).[3]伍卫秀,赵青,虞锦晖. 钢筋混凝土弯剪扭构件的受扭界限配筋[J].建筑结构,2009, 39(2):39-40.
[4]美国房屋建筑混凝土结构规范(ACI 318—05)及条文说明(ACI 318R—05)[M]. 张川,白绍良,钱觉时,译.重庆:重庆大学出版社,2007.