您现在的位置:建筑结构>> 期 刊>> 2010年>> 第02期>>正文内容
支管拉力作用下钢管K形节点承载力计算方法探讨
黄文金1,2,陈宝春2
摘 要
 
(1 福建农林大学,福州 350002; 2 福州大学,福州 350108)
[摘要]在统计分析19个钢管K形相贯节点试件失效模式和极限承载力的基础上,对我国《钢结构设计规范》(GB50017—2003)的承载力计算方法进行了分析。结果表明,受压支管内力引起节点失效时,节点承载力试验值与计算值总体上吻合较好;而受拉支管内力引起节点失效时,节点承载力的计算值明显小于试验值。进行了2个支管拉伸破坏的钢管K形相贯节点试验,结果进一步表明我国钢结构规范计算值偏于保守。提出了对支管拉力作用下K形节点承载力乘以增大系数的建议,建议方法计算精度明显提高且仍有足够的安全性。
[关键词]钢管结构;K形节点;极限承载力;计算方法
Analysis on strength calculation method of circular tubular K\|joint under tension force
Huang Wenjin1,2, Chen Baochun2(1 Fujian Agriculture and Forestry University, Fuzhou 350002, China; 2 Fuzhou University, Fuzhou 350108, China)
Abstract:Based on statistical anlysis of failure modes and ultimate bearing capacities of 19 circular tubular K-joints, the strength calculation method in Code for Design of Steel Structures (GB50017—2003) was discussed. It was shown  that calculation strength agreed well with test results for joint specimens failed by forces of web in compression. However, the calculation results were too smaller than those test ones for joint specimens failed by forces of web in tension. Two tests of K-joints subject to force of web in tension were carried out.It is further proved that the calculation strength by Code GB50017—2003 was too conserved. A method to increase calculation strength of K-joint for failure by forces of web in tension was proposed. The calculation accuracy was improved by the proposed method compared to the original one while the reserved safety was still enough.
Keywords:steel tubular structure;  K-joint; ultimate bearing capacity; calculation method
*国家自然科学基金项目(50578042)。
作者简介:黄文金,讲师,博士,E-mail: wenjinhuang@fzu.edu.cn
参考文献
[1]WARDENIER J, KUROBANE Y, PACKER J A, et al. Design Guider for Circular Hollow Section (CHS) Joints Under Predominantly Static Loading (1)[M]. Germany: CIDECT (Ed.) and Verlag TüV Rheinland, Cologne,  1991.
[2]YOSHIAKI KUROBANE, KENSHI OCHI. AWS versus. International design rules for circular tubular K-connections[J]. Engineering Structures, 1997, 19(3): 259-266.
[3]WANG B, HU N, KUROBANE,  et al. Damage criterion and safety assessment approach to tubular joints[J]. Engineering Structures, 2000 (22): 424-434.
[4]陈以一,陈扬骥.钢管结构相贯节点的研究现状[J].建筑结构,2002,32(7):52-55.
[5]QIAN X, ROBERT H DODDS, CHOO Y S. Elastic-plastic crack driving force for tubular K-joints with mismatched welds[J]. Engineering Structures, 2007 (29): 865-879.
[6]PACKER J A,HENDERSON J E.空心管结构连接设计指南[M]. 曹俊杰,译.北京:科学出版社,1997.
[7]WARDENIER J.钢管截面的结构应用[M]. 张其林,刘大康,译.上海:同济大学出版社,2004.
[8]GB50017—2003钢结构设计规范[S].北京:中国计划出版社,2003.
[9]舒兴平,朱邵宁,夏心红,等.长沙贺龙体育场钢屋盖圆管相贯节点足尺试验研究[J].建筑结构学报,2004,25(3):8-13.
[10]赵宪忠,陈誉,陈以一,等.平面K型圆钢管搭接节点静力性能的试验研究[J].建筑结构学报,2006,27(4):23-29.
[11]翟红,赵宪忠,陈以一,等.大直径圆钢管空间KK型相贯节点试验研究[J].工程力学,2002(S1):481-484.
[12]赵宏康,戴雅萍,吕西林.苏州国际博览中心屋盖结构分析和并联K形圆钢管相贯节点研究[J].建筑结构学报,2006,27(4):51-60.