您现在的位置:建筑结构>> 期 刊>> 2010年>> 第02期>>正文内容
无粘结预应力混合装配式联肢墙抗震性能分析
蔡小宁1,孟少平1,孙巍巍2,吴畅1
摘 要
1 东南大学混凝土及预应力混凝土结构教育部重点实验室,南京 210096; 2 南京理工大学,南京 210094)
[摘要]对无粘结预应力混合装配式联肢墙中普通钢筋与预应力筋的布置及其面积比对抗震性能的影响进行了研究,给出了合理的设计建议。对无粘结预应力混合装配式联肢墙和直接装配式联肢墙进行了对比试验研究,结果表明无粘结预应力装配式联肢墙具有“自恢复”的性能,卸载后残余变形小,非线性变形集中于连接区域,震后易修复,与直接装配式联肢墙相比,具有较好的耗能能力和较高的承载力。
[关键词]抗震性能;混合装配;耗能能力;残余变形;承载力
Study on seismic behavior of unbonded post-tensioned hybrid precast coupled wall
Cai Xiaoning1, Meng Shaoping1, Sun Weiwei2, Wu Chang1(1 Key Laboratory of Concrete and Prestressed Concrete Structures of Ministry of Education, Southeast University, Nanjing 210096,China; 2 Nanjing University of Science and Technology, Nanjing 210094,China)
Abstract:The effect of the arrangement of bar reinforcement and unbonded post-tensioned reinforcement and ratio of area of bar reinforcement to unbonded post-tensioned reinforcement on seismic behavior of hybrid reinforced precast coupled wall are analyzed, then appropriate design suggestions are proposed. Two specimens of unbonded post-tensioned precast coupled wall were tested, one was the hybrid precast coupled wall and the other was the direct precast coupled wall for comparison.The results validated that unbonded post-tensioned precast coupled wall has the ability of self-recovery,so residual deformation is small and it can be easily rehabilitated due to nonlinear deformation concentrates around the connection zones.The results also showed that hybrid precast coupled wall has the advantage of good energy dissipation and high ultimate capacity.
Keywords:seismic behavior; hybrid precast; energy dissipation; residual deformation;ultimate capacity
江苏省建设厅科技项目基金资助(JS2007ZB04)。
作者简介:蔡小宁,博士研究生,Email:fenyun0801@163.com。
参考文献
[1]孙巍巍,孟少平.后张无粘结预应力装配混凝土联肢抗震墙的连梁组合体抗侧性能[J].东南大学学报,2007,37(2):190-194.
[2]NAKAKI S D,STANTON J F,SRITHARAN S.An overview of the PRESSS five-story precast test building[J].PCI Journal, 1999, 44(2):26-39.
[3]ACI Innovation Group. ACI T1-2—03 Special Hybrid Moment Frames Composed of Discretely Jointed Precast and Post-Tensioned Concrete Members[S]. 2003.
[4]EI-SHEIKH M. Seismic Analysis Behavior and Design of Unbonded Post-tensioned Precast Concrete Frames[D].United States: Department of Civil and Environmental Engineering, Lehigh University,1997.
[5]STEFANO PAMPANIN. Analytical Modeling of the Seismic Behavior of Precast Concrete Frame Ductile Connections[D]. San Diego:University of California,2000.
[6]JOHN STANTON,WILLIAM C S, GERALDINE S C. A hybrid reinforced precast frame for seismic regions[J].PCI Journal, 1997,42(2):20-32.
[7]Specifications for Structures to Be Built in Disaster Areas[S].Ankara, Turkey: Ministry of Public works and settlement,1998.
[8]SEVKET OZDEN, ONUR ERTAS. Behavior of unbonded  post-tensioned precat concrete connections with different percentages of mild steel reinforcement[J].PCI Journal, 2007,52(2):32-44.
[9]孙巍巍.后张无粘结预应力装配式短肢剪力墙抗震能力及设计方法研究[D].南京:东南大学,2007.
下载地址

    你还没注册?或者没有登录?这篇论文要求至少是本站的注册会员才能阅读!

    如果你还没注册,请赶紧点此注册吧!

    如果你已经注册但还没登录,请赶紧点此登录吧!