您现在的位置:建筑结构>> 期 刊>> 2015年>> 第11期>>正文内容
基于性能的钢管再生混凝土柱抗震设计控制参数研究*
张向冈1,2 陈宗平2 薛建阳2 苏益声2
摘 要

1 河南理工大学土木工程学院, 焦作 454000  2 广西大学土木建筑工程学院, 南宁 530004

[摘要]针对钢管再生混凝土柱这种新型组合构件,进行了抗震性能设计的控制参数研究。引入了三水平地震设防水准。采用五档性能水准,给出了对应的破坏状态及宏观描述,并分别以水平位移角和损伤作为性能水准的量化指标。汇总了国内外47个圆钢管再生混凝土柱和36个方钢管再生混凝土柱的抗震试验数据,依据正态分布统计方法,确定了不同性能水准下的水平位移角限值;引入Park-Ang双参数模型评估钢管再生混凝土柱的地震损伤行为,对课题组的10个圆钢管再生混凝土柱和6个方钢管再生混凝土柱的累积损伤指标取平均值,确定了不同性能水准下的累积损伤指标限值。按照三水平地震设防水准和五档性能水准,建立了合理、实用的钢管再生混凝土柱的性能目标。

[关键词]钢管再生混凝土柱; 地震设防水准; 性能水准; 量化准则; 性能目标

中图分类号:TU398文献标识码:A文章编号:1002-848X(2015)11-0060-05

Research on the control parameters of seismic design based on performance of

 recycled aggregate concrete filled steel tube columns

Zhang Xianggang1,2, Chen Zongping2, Xue Jianyang2, Su Yisheng2

(1 School of Civil Engineering, Henan Polytechnic University, Jiaozuo 454000, China;

2 College of Civil Engineering and Architecture, Guangxi University, Nanning 530004, China)

Abstract:The control parameters of seismic

 design  based on performance performance were studied about the new combination component of recycled aggregate concrete filled steel tube columns. Earthquake fortification level of three stages was introduced.  Five performance levels were adopted to give the corresponding failure state and macroscopic description. Horizontal displacement angle and damage were selected as performance level quantitative indexes. The seismic test data were collected including 47 recycled aggregate concrete filled circular steel tube columns and 36 recycled aggregate concrete filled square steel tube columns, based on normal distribution statistical methods, the limit of horizontal displacement angle was determined under different performance levels. Double parameter model of Park-Ang was introduced to evaluate the  earthquake damage of recycled aggregate concrete filled steel tube columns. The limit of cumulative damage index was determined under different performance levels by the mean of cumulative damage index about 10 recycled aggregate concrete filled circular steel tube columns and 6 recycled aggregate concrete filled square steel tube columns. Reasonable and practical performance objectives of recycled aggregate concrete filled steel tube columns were established according to seismic fortification level of three stages and five performance levels.

Keywords:recycled aggregate concrete filled steel tube column seismic fortification level performance level quantitative criterion performance objective

*国家自然科学基金项目(51268004),广西自然科学基金项目(2012GXNSFAA053203),广西理工科学实验中心重点项目(LGZX201102),河南省高等学校重点科研项目(15A560008),河南理工大学博士基金项目(B2015-72)。

作者简介:张向冈,博士,讲师,Email: xgzhang@hpu.edu.cn

参考文献

1GB 500112010建筑抗震设计规范[S. 北京:中国建筑工业出版社,2010.

2]戴国莹. 建筑结构基于性能要求的抗震措施初探[J. 建筑结构,20003010):60-62.

3]汪梦甫,周锡元. 基于性能的建筑结构抗震设计[J. 建筑结构,2003333):59-61.

4]门进杰,史庆轩,周琦. 框架结构基于性能的抗震设防目标和性能指标的量化[J. 土木工程学报,2008419):76-82.

5]张向冈. 钢管再生混凝土构件及其框架的抗震性能研究[D. 南宁:广西大学,2014.

6]钱稼茹,徐福江. 钢筋混凝土剪力墙基于位移的变形能力设计方法[J. 清华大学学报:自然科学版,2007473):1-4.

7]韩林海,杨有福. 现代钢管混凝土结构技术[M. 2. 北京:中国建筑工业出版社,2007.

8PARK Y, ANG A. Mechanistic seismic damage model for reinforced concreteJ. Journal of Structural Engineering, 1985, 111(4): 740-757.

9]何利,叶献国. Kratzig Park-Ang损伤指数模型比较研究[J. 土木工程学报,20104312):1-6.