摘 要

(1 广州大学土木工程学院,广州 510006;2 万科企业股份有限公司,深圳 518049)
[摘要]结合国内首栋预制装配整体式混凝土结构试验楼工程,对装配整体式叠合连续楼板进行现场加载试验研究。从内力重分布的角度,分析了叠合连续楼板在使用阶段的变形及受力特征。试验结果表明,装配整体式叠合连续楼板具有较好的整体工作性能;除具有单向叠合连续板的内力重分布特征外,还具有沿整体后浇层向周边板块内力调整的特点,具有一定的双向板受力特性。
[关键词]预制混凝土;叠合连续楼板;内力重分布;整体后浇层
Full scale experimental study on assembled monolithic composite slabs
Zhang Jichao1, Xu Yong1, Wang Yun2(1 School of Civil Engineering, Guangzhou University, Guangzhou 510006, China; 2 Vanke Co., Ltd., Shenzhen 518049, China)
Abstract:Being related to the first assembled monolithic precast concrete testing-building in our country, the loading experimental study is introduced on assembled monolithic composite continuous slab. From the view of internal force redistribution, the displacement and internal force of composite continuous slab in using times were analyzed. The experiment result indicates that assembled monolithic composite continuous slab has well monolithic working performance. It not only have the internal force redistribution characteristic belong to unilateralist slab, but also have the characteristic of adjusting internal force to around area through monolithic casting layer. And there are some bidirectional loading performance in the slab.
Keywords:precast concrete; composite continuous slab; internal force redistribution; monolithic casting layer
国家科技支撑计划重点项目(2006BA27B05)。
作者简介:张季超,教授,Email:zhangjichao1956@126.com。
参考文献
[1]周旺华. 现代混凝土叠合结构[M]. 北京:中国建筑工业出版社,1998.
[2]邓志恒,陆春阳. 钢筋砼连续叠合梁受弯性能及设计方法研究[J].广西科学,2000,7(3):161-164.
[3]李耀庄,蒋青青,黄赛超,等.混凝土倒T形叠合连续板的试验研究[J].中南工业大学学报,2003,34(6):695-698.
[4]俞良群.冷轧扭钢筋混凝土连续梁、板塑性调幅设计[J].工业建筑,1999,29(8):17-19.
[5]GB50010—2002混凝土结构设计规范[S].北京:中国建筑工业出版社,2002.
[6]张季超,王慧英,楚先峰,等.预制混凝土结构的效益评价及其在我国的发展[J].建筑技术,2007,1:9-11.
[7]姚振纲,刘祖华.建筑结构试验[M].上海:同济大学出版社,1996.