济南奥体中心体育馆火灾后检测鉴定
翟传明1,傅学怡2,杨想兵2,谢瑜昱1,夏宗义1
摘 要

(1 国家建筑工程质量监督检验中心,北京 100013; 2 中建国际(深圳)设计顾问有限公司,北京 100044)
[摘要]济南奥体中心体育馆火灾后,对主体钢结构采用了对比硬度回弹和钢材金相组织分析的方法进行现场检测,同时对网壳变形进行测量,对构件内力补充监测数据,并进行结构内力计算与分析。将检测结果、变形测量结果、构件内力监测数据与理论计算分析结果进行比较分析,对火灾后结构的安全性做出正确的鉴定评价。
[关键词]火灾;检测鉴定;安全性鉴定;网壳
Inspection assessment on stadium of Jinan Olympic Sports Center after fire
Zhai Chuanming1,Fu Xueyi2,Yang Xiangbing2,Xie  Yuyu1,Xia Zongyi1(1 National Centre for Quality Supervision & Test of Building Engineering,Beijing 100013,China; 2 China Construction Design International,Beijing 100044, China)
Abstract:Rebound hardness comparision and steel microstructure analysis method on field have been used on the inspection of the main steel structure of Jinan Olympic Sports Centre Stadium. Simultaneously, the deformation of the reticulated shell was measured, the inspection data of the internal force in members were complemented, and the structural intenal forces have been calculated and analyzed. Results of inspection and measurement were compared with the theoretical analyzed calculation results. The structural safety can be evaluated accurately by inspection after fire.
Keywords: fire; identification and inspection; safety evaluation; reticulated shell
作者简介:翟传明,硕士,高级工程师,E-mail: zcmcabr@sina.com。
参考文献
[1]GB/T17394—1998金属里氏硬度试验方法[S].北京:中国标准出版社,1998.
[2]GB/T13298—91金属显微组织检验方法[S].北京:中国标准出版社,1992.
[3]JGJ8—2007建筑变形测量规程[S].北京:中国建筑工业出版社,2008.