外保温叠合填充墙板框架结构振动台试验研究*
陆天佐,王曙光,杜东升,李威威
摘 要

(南京工业大学土木工程学院, 南京 211816

 

[摘要]对两层钢筋混凝土纯框架结构及外保温叠合填充墙板的框架结构进行了足尺振动台试验,对比研究了框架结构及外保温叠合填充墙板的破坏过程和破坏模式,分析了外保温叠合填充墙板对钢筋混凝土框架结构的周期、阻尼比、刚度、楼层加速度以及楼层位移的影响。研究结果表明:与钢筋混凝土纯框架结构相比,外保温叠合填充墙板框架结构阻尼比有大幅度的提高,说明外保温叠合填充墙板比一般填充墙板耗能能力强;结构的加速度放大系数随着地震烈度增加而减小,随着楼层高度的增加而增大;结构的楼层位移模式呈剪切型变形特点,层间位移角小于规范限值;填充墙体与框架主要靠钩头螺栓连接,从弹性到塑性的过程中,除了在墙板的脚部出现裂缝外,没有出现整体垮塌现象,说明填充墙体与框架的连接措施可靠,可以在地震区推广使用。

[关键词]台试验外保温叠合填充墙板;  抗震性能; 框架结构; 振动

中图分类号:TU375.4    文献标识码:A    文章编号:1002-848X(2015)04-0073-05

 

Shaking table test study on frame structure with external insulation composite filled wallboard

Lu Tianzuo, Wang Shuguang, Du Dongsheng, Li Weiwei

 (School of Civil Engineering, Nanjing University of Technology, Nanjing 211816, China)

 

Abstract:

In order to investigate the failure process and failure mode of the pure reinforced concrete frame structure and filled wallboard, full\|scale model of a two-storey pure frame structure and frame structure with external insulation composite filled wallbord were conducted by shaking table tests, and the effects of external insulation composite filled wallbord on period, damping ratio, stiffness, floor acceleration and floor displacement of reinforced concrete frame structure were analyzed. The results show that compared with the pure  reinforced concrete frame structure, the damping ratio of the frame structure with external insulation composite filled wallbord increases greatly, so its energy dissipation ability is better than ordinary filler wall. The acceleration amplification coefficient of the structure decreases with the increase of seismic intensity, and increases with the increase of floor height. The floor displacement model of the structure assumes the deformation characteristics of shear type, and the inter\|layer displacement angle is less than the limit. The filled wallbord connects with the frame mainly by hook bolts, and there is no overall collapse phenomenon from elastic stage to plastic stage except the wall foot cracks. The connection measures are reliable between the wallboard and the frame and the connection measures can be used widely in the earthquake zone.

Keywords:external insulation composite filled wallboard; seismic performance; frame structure; shaking table test

 

*国家科技支撑计划资助(2012BAJ06B00)。

作者简介:陆天佐,硕士研究生,Email:lutianzuo@126.com

 

参考文献

1]曹万林,王光远,吴建友.轻质填充墙异型柱框架结构层刚度及其衰减过程的研究[J.建筑结构学报,1995, 16(5):2031.

2CHAKER A A, CHERIFATI A. Influence of masonry infill panels on the vibration and stiffness characteristics of RC frame building J. Earthquake Engineering and Structural Dynamics, 1999,12(3):1061106.

3]黄靓,施楚贤,熊辉.带砌体填充墙结构在地震作用下的安全性质疑[J.建筑结构,2005,35(3):5765.

4]清华大学土木结构组,西南交通大学土木结构组,北京交通大学土木结构组. 汶川地震建筑震害分析[J.建筑结构学报,2008,29(4): 19.

5]李建中,吕西林,李翔,.汶川地震中钢筋混凝土框架结构的震害[J.结构工程师,2008,24(3):911.

6]管民生,万新,杜宏彪.填充墙对RC框架结构抗震性能影响及其模型研究[J.广东工业大学报,2010,27(1):7174.

7]王滋军,刘伟庆,王宁,.钢筋混凝土叠合剪力墙的预制墙体外壳结构及其拼接方法:中国, CN2012102405056P 20121024.

8]王滋军,翟文豪,刘伟庆,等.新型钢筋混凝土叠合结构体系及其改进技术[J.混凝土,2012,40(10):128131.

下载地址

    你还没注册?或者没有登录?这篇论文要求至少是本站的注册会员才能阅读!

    如果你还没注册,请赶紧点此注册吧!

    如果你已经注册但还没登录,请赶紧点此登录吧!