您现在的位置:建筑结构>> 期 刊>> 2015年>> 第03期>>正文内容
钢管与管外混凝土界面粘结抗剪能力试验研究*
钱稼茹1,2,赵作周1,2,纪晓东1,2
摘 要

1 清华大学土木工程安全与耐久教育部重点实验室, 北京 100084

2 清华大学土木工程系, 北京 100084

 

[摘要]为研究并揭示钢管混凝土叠合柱的钢管与管外混凝土界面的粘结抗剪能力,完成了10个试件的推出试验,其中3个试件的钢管外壁未焊接抗剪连接件,4个试件的钢管外壁焊接钢筋环、3个试件的钢管外壁焊接栓钉作为抗剪连接件。试件的破坏形态为钢管混凝土被推出,钢筋环的焊缝及栓钉的栓杆被剪断;未焊接抗剪连接件试件的实测界面抗剪粘结强度略大于1.0MPa;钢筋环直径由6mm增大为8mm、或由1根增加为2根、或栓钉直径由10mm增大为16mm,界面的受剪承载力增大;1根直径8mm的钢筋环的受剪承载力大于4根直径16mm的栓钉的受剪承载力。钢筋环及栓钉的受剪承载力试验值大于公式计算值。提出了钢管与管外混凝土界面抗剪粘结设计建议。

[关键词]钢管与管外混凝土界面; 粘结抗剪性能; 受剪承载力; 推出试验

中图分类号:TU398.1    文献标识码:A    文章编号:1002-848X(2015)03-0012-05

 

Test study on shearbond capacity of steel tubeout of tube concrete interface

Qian Jiaru1,2 Zhao Zuozhou1,2 Ji Xiaodong1,2

 (1 Key Laboratory of Civil Engineering Safety and Durability of China Education Ministry, Tsinghua University,

Beijing 100084, China;

2 Department of Civil Engineering, Tsinghua University, Beijing 100084, China)

 

Abstract:To study and reveal the shearbond capacity of the steel tubeout of tube concrete interface for steel tubereinforced concrete columns, pushout tests of 10 specimens were performed. Among 10 specimens, 3 specimens had no shear connector on the steel tube, 4 specimens had steel bar rings and 3 specimens had shear studs welded on the steel tube respectively as the shear connector. The failure mode of the specimens was that the concrete filled steel tube was pushed out, both the welds of steel bar ring and the stud bar were shear broken. The measured shearbond strength of the interface without shear connector was a little bit larger than 10MPa. Increasing the diameter of the steel bar ring from 6mm to 8mm, or increasing the number of the steel bar ring from 1 to 2, or increasing the diameter of the stud from 10mm to 16mm, led to an increase of the shear capacity of the interface. The shear capacity of one 8mm diameter steel bar ring was larger than those of four 16mm diameter studs. The measured shear capacities of the steel bar ring and of the stud were larger than those of the calculated values. The shearbond design recommendations for the steel tubeout of tube concrete interface were presented.

Keywords:steel tubeout of tube concrete interface; shearbond behavior; shear capacity; pushout test

*国家科技支撑计划课题(2012BAJ07B012)

作者简介:钱稼茹,教授, Email: qianjr@mail.tsinghua.edu.cn

 

参考文献

1CECS 1882005 钢管混凝土叠合柱结构技术规程[S. 北京:中国计划出版社,2005.

2]钱稼茹,康洪震. 钢管高强混凝土组合柱抗震性能试验研究[J.建筑结构学报,2009,30(4):8593.

3]薛立红,蔡绍怀. 钢管混凝土柱组合界面的粘结强度(上)[J.建筑科学,1996,12(3):2628.

4]薛立红,蔡绍怀.钢管混凝土柱组合界面的粘结强度(下)[J.建筑科学,1996,12(4):1923.

5]刘永健,池建军. 钢管混凝土界面抗剪粘结强度的推出试验[J. 工业建筑,2006,36(4):7880.

6]薛立红,蔡绍怀. 钢管混凝土抗剪连接件的试验研究[J.建筑科学,1998,14(1):1321.

7]吴美艳, 余天庆. 剪力环对钢管混凝土粘结强度影响的试验[J. 湖北工学院学报,2004,19(1):68.

8]薛立红,蔡绍怀. 钢管混凝土界面附近的局部承压实验研究[J.建筑科学,1998,14(4):918.

9GB 500172003钢结构设计规范[S. 北京:中国计划出版社,2003.

10]叶列平. 混凝土结构设计[M. 北京:中国建筑工业出版社,2012.

11]聂建国,谭英,王洪全. 高强混凝土组合梁栓钉剪力连接件的设计计算[J. 清华大学学报:自然科学版,1999, 39(12):9497.

 

12]蔡绍怀. 现代钢管混凝土结构[M. 北京:人民交通出版社,2003.