[摘要]锦州国际酒店塔楼平面为南北两个半径约为50m的1/4圆环围合成中空的近似椭圆环形平面,南北两环在端部相连,北环为框剪结构,南环在6层及以下抽柱转换且径向大部分区域为单跨框架结构。南北两环以及塔楼径向和环向的结构体系各不相同。除了设定塔楼整体的抗震性能目标外,对不同区段分别设置相应的二道防线,同时在设备层加强南北两环的连接,并在南环设置了斜撑结构,还按高于规范要求的标准对南环框架结构承担的剪力进行了调整,同时对南环单跨部分单独进行验算,提高了结构安全性。
[关键词]椭圆环形; 抽柱转换; 单跨框架; 径向; 环向; 二道防线
中图分类号:TU973+.16      文献标识码:A      文章编号:1002-848X(2014)24-0043-06
 
Structural design and analysis for Jinzhou International Hotel Tower
Ma Hui, Wang Yang
 (Arup, Shenzhen 518048, China)
 
Abstract: Jinzhou International Hotel tower building has an ellipse ring plane consisting of two quarter rings with radius of 50m in south and north. The two arcs contacts with each other at the ends. The northern arc is in frame-shear wall system, while the major part of the southern one is in single span frame along radial direction with transfers at 6 floor due to column reducing underneath. The structural systems between the southern and the northern arc and between the radial direction and the hoop direction of the tower are different. The overall seismic performance objective of the tower was set up and second defensive lines were also set up for various parts of the tower. The connection of the two arcs at mechanical floor was enhanced, bracing was also introduced for the single span frame of the southern arc. The shear force taken by the single span frame of the southern arc was increased in terms of the requirement of the codes, and the bearing capacity of the southern arc was checked independently, which improves the safety of the structure.
Keywords:ellipse ring; transfer with reduced column; single span frame; radial direction; hoop direction; second defensive line
作者简介:马晖,学士,副董事,Email:h.ma@arup.com。
 
参考文献
[1]JGJ 3—2002高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社,2002.
[2]GB 50011—2001建筑抗震设计规范[S].2008年版. 北京:中国建筑工业出版社,2008.
[3]FEMA356 Presandard and commentary for the seismic rehabilitation of buildings [S]. Federal Emergency Management Agency, 1997.
[4]辽宁省地震研究所. 锦州市酒店、会展综合发展项目工程场地地震安全性评价[R].2006.
下载地址

    你还没注册?或者没有登录?这篇论文要求至少是本站的注册会员才能阅读!

    如果你还没注册,请赶紧点此注册吧!

    如果你已经注册但还没登录,请赶紧点此登录吧!