高层非对称连体结构屈曲约束构件耗能减震分析
王赞,杨超,许文杰,王寒冰,刘国友
摘 要

(中国建筑标准设计研究院, 北京 100048

[摘要]对于高层非对称连体结构,考虑到强连体、弱连体的利弊及在端支座设置阻尼器减震结构的弊端,提出一种带耗能机制的新型连体结构。该新型连体结构在连体中部采用水平及斜向耗能构件代替弦杆及腹杆;针对此连体结构,给出了地震作用下各构件的抗震性能目标;对算例进行了多遇地震弹性及罕遇地震弹塑性计算,结果表明,此新型连体结构的设计可减弱主体结构在罕遇地震作用下的破坏,整体结构能达到预期的抗震性能设计目标。同时也指出此新型连体结构设计时需要注意的部分问题。

[关键词]连体结构; 屈曲约束构件; 耗能减震分析; 抗震性能设计

中图分类号:TU973      文献标识码:A      文章编号:1002-848X(2014)18-0089-05

Energy-dissipated analysis of buckling restrained members for high-rise asymmetric connected structures

Wang Zan, Yang Chao, Xu Wenjie, Wang Hanbing, Liu Guoyou

 (China Institute of Building Standard Design and Research, Beijing 100048, China)

Abstract: Considering both advantages and disadvantages of the strong-connected structure and the weak-connected structure as well as the disadvantages of energy-dissipated structures with damper at the end support, a new connected structure with energy-dissipated mechanism was proposed for high-rise asymmetric connected structures. In the new connected structure, horizontal and diagonal energy-dissipated members were set in the middle of the connected body to replace the chords and braces. Performance seismic design objectives were given for all the members under the earthquake. Elastic calculation under the frequent earthquake and elastic-plastic calculation under the rare earthquake were carried out on an example respectively. The results show that design of the new connected structure can reduce the damage of the main structure under the rare earthquake, and the entire structure can reach the expected performance seismic design objectives. Meanwhile, some problems that need pay attention to were pointed out to the design of the new connected structure.

Keywords: connected structure; buckling restrained member; energy-dissipated analysis; performance seismic design

作者简介:王赞,硕士,工程师,Email:wangz174255@126.com

参考文献

1]农兴中,伍永胜,郁银泉,等.某超高层建筑L形连体结构方案研究与设计[J.建筑结构,20124211:71-75.

2]侯家健,李桢章,韩小雷,等.双塔连体超高层建筑结构连接方案比较[J.工程抗震[3]吴耀辉,娄宇,李爱群.对称双塔连体结构采用粘滞流体阻尼器的消能减震分析[J.建筑结构,2008,388:91-93.

4]杨佑发,刘泳伶,凌玲,等.连体的连接方式对大底盘双塔连体耗能减震结构地震响应的影响[J.工业建筑,2013,432:29-33.

5XU Y L, HE Q, KO J M. Dynamic response of damper connected adjacent buildings under6ZHANG W S, XU Y L. Dynamic characteristics and seismic response of adjacent buildings linked by discrete dampersJ.Earthquake Engineering and Structural Dynamics, 1999,2810:1163-1185.

7]閣东东,朱宏平,陈晓强.两相邻结构地震动响应被动优化控制研究[J.振动工程学报,2008215:482-487.