(太原理工大学建筑与土木工程学院, 太原 030024)
[摘要]为了提高桩与承台连接节点的承载力,对管桩进行劲性填芯,并对劲性填芯管桩及普通填芯管桩进行室内节点抗震性能试验,对比分析了两种管桩在水平往复荷载作用下的荷载-位移曲线、荷载-应变曲线、裂缝发展情况及抗弯能力。结果表明,劲性填芯能够使锚固钢筋和管桩更好地发挥其性能,且能大幅度提高桩与承台连接节点的水平承载力、位移及延性。
[关键词]劲性填芯管桩; 桩基; 水平往复荷载; 节点; 承载力
中图分类号:TU473.1+2 文献标识码:A 文章编号:1002-848X(2014)17-0075-04
Experimental research on seismic performance of steel composite filling core pipe pile joints
Zhang Wei, He Wubin, Guo Zhaosheng, Bai Xiaohong
(College of Architecture and Civil Engineering, Taiyuan University of Technology, Taiyuan 030024, China)
Abstract: To improve the bearing capacity of the connection joint between pile and pile cap, the pipe pile was filled with steel. The indoor seismic performance experiments were carried out on the steel composite filling core pipe pile and common material composite filling core pipe pile respectively. Comparison analyses were carried out on the load-displacement curve, the load-strain curve, crack development situation and the resistance to bending of two kinds of piles under the horizontal reciprocating load. The results show that steel composite filling core can not only make performances of the anchorage rebar and pipe pile play well, but also improve the horizontal bearing capacity, ductility and displacement of the connection joint between pile and pile cap greatly.
Keywords:steel composite filling core pipe pile; pile foundation; horizontal reciprocating load; joint; bearing capacity
*山西省留学人员科技活动择优项目(80010402020028)。
作者简介:张伟,硕士研究生,Email:507161644@qq.com。
参考文献
[1]宋寅,柳炳康,李建宏,等. 填芯与非填芯预应力混凝土管桩抗弯性能的比较[J].合肥工业大学学报:自然科学
版,2007,30(5):607-610.
[2]张星宇,柳炳康,凌应轩,等. 预应力混凝土管桩与承台结合部抗剪承载力的试验研究[J].建筑结构,2008,38(4):11-14.
[3]戎贤,王旭月,李艳艳. 掺入钢纤维的PHC管桩抗震性能的试验研究[J]. 建筑结构,2014,44(8):11-14.
[4]戎贤,李鹏飞.预应力混凝土管桩节点抗震性能研究[J].工业建筑,2013,43(8):94-97.
[5]倪国泉,杨军,潘鹏,等.预应力混凝土空心方桩承台节点抗震性能试验研究[J]. 地震工程学报, 2013, 35(2):246-251.
[6]GJ 94—2008 建筑桩基技术规范[S]. 北京:中国建筑工业出版社,2008
[7]10G409 预应力混凝土管桩图集[S]. 北京:中国计划出版社, 2010.