您现在的位置:建筑结构>> 期 刊>> 2014年>> 第17期>>正文内容
大型显示屏支撑结构抗震分析与节点性能研究
姚云龙,章跃军
摘 要

(华信咨询设计研究院有限公司, 杭州 310014)

[摘要]根据三个水准抗震设防目标研究大型显示屏支撑结构的抗震特性,提出相应水准目标下的设计原则。采用SAP2000软件分析三个水准目标下支撑结构的变形及应力特性,研究支撑结构单体计算时与考虑主体结构影响进行整体计算时的差别。结合“强节点弱构件”的失效机制采用ANSYS软件进行节点深化分析。结果表明,支撑结构平面变形受主体结构的影响较大,计算时应考虑主体结构的影响,支撑结构的竖向变形采用底层支撑节点变形控制,其竖向布置应避开主体结构薄弱层,支撑节点构件可通过在内部设置十字形加劲肋提高承载力。

[关键词]电子显示屏; 支撑结构; 有限元分析; 节点; 十字加劲肋

中图分类号:TU391      文献标识码:A      文章编号:1002-848X(2014)17-0024-06

Seismic performance analysis and joint behaviour research of the supporting structure of large screen

Yao Yunlong, Zhang Yuejun

 (Huaxin Consulting and Designing Institute Co., Ltd., Hangzhou 310014, China)

Abstract:According to the three earthquake performance objectives, the seismic performance of the supporting structure of large screen was analyzed, and the seismic design principles for corresponding objectives were proposed. Using the finite element analysis program SAP2000, the deformation and stress characteristics of the supporting structure were analyzed, and the differences between separate calculation model and global calculation model taking into account the main structure influence were studied. The joint failure mechanism based on the general design rule of “strong joint, weak member” was investigated deeply by ANSYS. The simulation results show that the main structure has great influence on the plane deformation of the supporting structure and the influence of the main structure on the calculation of the supporting structure should be considered. The vertical deformation of the supporting structure was controlled by the deformation of the underlying supporting joint, and the vertical layout of the supporting structure should avoid weak position of the main structure. The bearing capacity of the supporting joint could be improved by the internal cross stiffener.

Keywords: electronic screen; supporting structure; finite element analysis; joint; cross stiffener

作者简介:姚云龙,硕士,工程师,一级注册结构工程师,注册土木工程师(岩土),一级注册建造师,注册咨询工程师,Emailyaoyl@hxdi.com

参考文献

1]王元清,李勇,石永久.强震作用下玻璃建筑的震害分析[C//汶川地震建筑震害调查与灾后重建分析报告.北京:中国建筑工业出版社,2008.

2GB 500112010 建筑抗震设计规范[S.北京:中国建筑工业出版社,2010.

3]张其林.玻璃幕墙结构设计[M.上海:同济大学出版社,2007.

4]沈之容,李冰心.楼顶广告牌结构基本自振周期计算方法研究[J.建筑结构,2012423):75-77.

5]黄小坤,林祥,黄拥军. 陶板幕墙模拟地震振动台试验研究[J.建筑结构,200636(10)95-97.

6GB 500172003 钢结构设计规范[S.北京:中国计划出版社,2003.

7]郭峰,黄用军,傅学怡.平安金融中心第11层带状桁架节点性能分析[J.建筑结构,2013434):78-82.

8]高振世.建筑结构抗震设计[M.北京:中国建筑工业出版社,1995.

下载地址

    你还没注册?或者没有登录?这篇论文要求至少是本站的注册会员才能阅读!

    如果你还没注册,请赶紧点此注册吧!

    如果你已经注册但还没登录,请赶紧点此登录吧!