冷却塔筒壁初始几何缺陷的分析计算及处理
李思明 金国芳 陈志强 石 昊
摘 要
(同济大学结构工程与防灾研究所  上海  200092)
[提要]  某座钢筋混凝土双曲线型冷却塔由于施工不当,筒壁出现局部凹凸,双曲线局部失形。采用有限元法对该冷却塔进行了内力分析和强度验算,分析了筒壁出现这些初始几何缺陷对冷却塔受力的影响,并提出了合理可行的结构加固方案,使其花费少量的资金加固后,确保冷却塔能安全运行。
[关键词]  双曲线冷却塔  筒壁几何缺陷  有限元  碳纤维  加固
Analysis and Treatment of a Cooling Tower with Geometrical Imperfections in Shell/Li Siming, Jin Guofang, Chen Zhiqiang, Shi Hao(Research Institute of Structural Eng. and Disaster Reduction, Tongji University, Shanghai 200092, China)
Abstract:Geometrical imperfection was found on a reinforced concrete hyperbolic cooling tower due to inappropriate construction. Finite element analysis is implemented to study the influence of initial fault upon the safety of the cooling tower. The internal stress and the loading capacity of the tower are checked with the finite element results. And feasible strengthening scheme with externally bonded CFRP is proposed to recover the safety of the tower with relatively low costs.
Keywords: hyperbolic cooling tower;geometrical imperfections in shell;finite element;CFRP;Strengthening