您现在的位置:建筑结构>> 期 刊>> 2013年>> 增刊S1(下)>>正文内容
超高层建筑结构时变作用耦合效应分析方法*
章建波1,严从志2,郁冰泉2,赵 昕3
摘 要

1 正荣御园(上海)置业发展有限公司,上海 2001202 同济大学建筑工程系,上海 2000923 同济大学建筑设计研究院(集团)有限公司,上海 200092

[摘要传统的超高层建筑时变分析分析方法是通过结构弹性时变分析得出结构的内力时程进而得出构件的非弹性变形时程,而并未考虑内力时程与变形时程之间的相互关联性。事实上,这种由于内力时程与变形时程之间的相互耦合作用而产生的结构内力以及变形差异在设计过程中是不可忽略的。本文基于超高层建筑结构的非弹性时变作用分析方法,分别对竖向构件的变形以及结构的强度设计进行计算,得出考虑耦合作用的时变分析方法在设计过程中与传统的结构设计方法的差异。

[关键词时变作用;耦合效应;竖向变形;超高层结构;结构设计

中图分类号:TU973.2      文献标识码:A      文章编号:1002-848X(2013)S1-1000-04

*上海市科技攻关计划资助(编号:09dz1207704);上海市青年科技启明星计划(跟踪)资助(编号:11QH1402700)。

通讯作者:郁冰泉,Email:ybqcxx@126.com

Coupling effect analysis of time-varying action for super tall building structures

Zhang Jianbo1, Yan Congzhi 2, Yu Bingquan 2, Zhao Xin 3

(1 Zhenro Royal Garden (Shanghai) Development Company, Co., Ltd., Shanghai 200120,China2 Department of Building Engineering, Tongji University, Shanghai 200092, China3 Tongji Architectural Design (Group) Co., Shanghai 200092, China)

Abstract: The forces of super tall building structures is obtained by the structural elastic time-varying  analysis method in the traditional time-varying analysis, thus derived inelastic deformation of time-histories of components, without considering the coupling effect between internal forces and deformation of time-histories. In fact, the structural internal forces and different deformation produced by the mutual coupling effect between internal forces and deformation of time-histories can't be ignored in the design process. The deformation of the vertical members and the design of structure strength have been calculated based on the inelastic time-varying analysis method of the super  high-rise structures in this paper to obtain the differences between the time-varying analysis methods considering the coupling effect and the traditional structural design methods.

Keywords: Time-varying effect; coupling effect; vertical deformation; super high-rise structures; structural design

下载地址

    你还没注册?或者没有登录?这篇论文要求至少是本站的注册会员才能阅读!

    如果你还没注册,请赶紧点此注册吧!

    如果你已经注册但还没登录,请赶紧点此登录吧!