- 摘 要
-
(广州瀚华建筑设计有限公司, 广州 510655)
[摘要]针对一栋总高200m、首层层高30m的板式转换的超高超限工程,比较了高位转换层的三种结构形式,介绍了本工程在小震、中震、大震作用下的各项总体计算结果,着重介绍了针对高位转换层而展开的各项计算工作及所采取的抗震措施,并分析了四种侧向刚度比算法对本工程的适用性,最后介绍了本工程的振动台试验结果。结果表明,本工程的受力和抗震性能满足要求,设计是可行的。
[关键词]高位转换层; 侧向刚度比; 算法; 厚板转换; 动力弹塑性分析; 屈曲分析
中图分类号:TU973 文献标识码:A 文章编号:1002-848X(2014)10-0037-09
Out-of-code design of the high transfer-story in a super-tall building
Chen Jun
(Guangzhou Hanhua Architects+Engineers Co., Ltd., Guangzhou 510655, China)
Abstract: Aiming at an out-of-code super-tall building with height of 200 metres and 30 metres high plate-transfer story in the first floor, three structural forms of high transfer-story were compared, and the whole integral calculation results were introduced under the frequent earthquake, the medium earthquake and the rare earthquake. Calculations and seismic measures aimed at the high transfer-story were emphasized, and the applicability of four calculation methods of the lateral stiffness ratio in this project was introduced. Finally, the results of the shaking table test were introduced. The results show that the bearing capacity and seismic performance of the project can meet the requirements and the design is feasible.
Keywords: high transfer-story; lateral stiffness ratio; arithmetic; thick plate transition; dynamic elastic-plastic analysis; buckling analysis
作者简介:陈军,硕士,高级工程师,一级注册结构工程师,副总工程师,Email:chenjun@gzhanhua.com。
参考文献
[1]JGJ 3—2002 高层建筑混凝土结构技术规程[S]. 北京:中国建筑工业出版社,2002.
[2]GB 50011—2010 建筑抗震设计规范[S]. 北京:中国建筑工业出版社,2010.
[3]徐培福,傅学怡,王翠坤,等.复杂高层建筑结构设计[M]. 北京:中国建筑工业出版社,2005.
[4]DBJ/T 15-46—2005 广东省实施《高层建筑混凝土结构技术规程》(JGJ 3—2002)补充规定[S]. 北京:中国建筑工业出版社,2005.
[5]周福霖,黄襄云,马玉宏,等.广州万科江湾东一期地震台抗震性能试验报告[R].广州:广州大学国家抗震减灾重点实验室,2007.
[6]容柏生,汪大绥,钱稼茹,等. 广州万科江湾东一期超限审查专家组审查意见[R]. 2007.