- 摘 要
-
(沈阳新大陆建筑设计有限公司, 沈阳 110179)
[摘要]短柱基础可有效减小底层柱计算长度,满足底层侧向刚度要求。对多层框架采用不同高度及截面尺寸的短柱基础与按以短柱顶为嵌固端进行简化计算分析比较,结果表明不能按以短柱顶为嵌固端进行简化计算。通过工程设计实例介绍了采用短柱基础的多层框架的设计方法,即设计时可将短柱层设为一个结构层,再将上部结构嵌固于短柱顶及基础顶分别进行计算,一层梁、柱按两次计算结果的较大值进行设计配筋,其他构件按有短柱层计算结果设计配筋。
[关键词]短柱基础; 多层框架; 计算长度; 刚度比
中图分类号:TU318.2 文献标识码:A 文章编号:1002-848X(2014)02-0071-04
Design of multilayer frame structure with puncheon foundation
Dong Qihao
(Shenyang New World Architecture Design Co., Ltd., Shenyang 110179, China)
Abstract: By using puncheon foundation, the effective length of bottom columns can be reduced and lateral stiffness of bottom layer meet requirements of the code. Compared simplified calculation results of multilayer frame with application of different height and size puncheon foundation and set the embedded end on the top of puncheon foundation show that it is improper to set the embedded end on the top of puncheon foundation. The design method of multilayer frame with puncheon foundation was introduced based on practical projects as follows. Puncheon foundation can be set to a structure layer, and then set the embedded end of superstructure on the top of puncheons or the top of the foundation separately to calculate. Beams and columns in first layer are reinforced according to larger calculated values of models with different embedded end locations and other components are reinforced according to calculated values of the model with puncheon foundation.
Keywords: puncheon foundation; multilayer frame; effective length; stiffness ratio
作者简介:董启灏,硕士,教授级高级工程师,Email: nwdqh@163.com。
参考文献
[1]GB 50011—2010 建筑抗震设计规范[S].北京:中国建筑工业出版社,2010.
[2]GB 50007—2011建筑地基基础设计规范[S]. 北京:中国建筑工业出版社,2012.
[3]王允锷.短柱基础在多层框架中的运用[J]. 建筑结构,2003,33(10):48-50.