您现在的位置:建筑结构>> 期 刊>> 2014年>> 第01期>>正文内容
钢板栓筋连接高强箍筋约束混凝土柱的抗震性能试验研究*
李青宁1,张振成1,于庆荣2,姜维山1
摘 要

(1 西安建筑科技大学土木工程学院, 西安 710055 2 天津大学建筑工程学院, 天津 300072)

 

摘要]提出装配框架柱的一种新型连接型式——钢板栓筋连接型式。采用足尺模型,设计了2个钢板栓筋连接高强箍筋约束混凝土柱和2个对比现浇普通箍筋柱。通过拟静力低周反复加载试验,并与现浇普通箍筋柱对比,研究钢板栓筋连接高强箍筋约束混凝土柱的承载能力和抗震性能。观测了4个试件受力→变形→损伤→裂缝→屈服的全过程,并分析各试件的破坏特征、滞回曲线、骨架曲线、刚度衰减、位移延性、耗能能力等。试验表明:在相同条件下,钢板栓筋连接高强箍筋约束混凝土柱具有与现浇普通箍筋柱相当的承载力,其抗震性能良好;连接处采用焊接及水平栓筋的钢板栓筋连接高强箍筋约束混凝土柱是可靠的。

关键词]高强螺旋箍筋; 约束混凝土; 装配式柱; 水平栓筋; 抗震性能

中图分类号:TU756.4+1      文献标识码:A      文章编号:1002-848X(2014)01-0042-07

 

Experimental research on seismic performance of the fabricated confined concrete columns with steel plate and horizontal strengthened bars

Li Qingning1, Zhang Zhencheng1, Yu Qingrong2, Jiang Weishan1

(1 School of Civil Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China; 2 Architectural and Civil Engineering Institute, Tianjin University, Tianjin 300072, China)

 

Abstract: A new connection type of frame fabricated columns with steel plate and horizontal strengthened bars was proposed. By using of the comparable full scale model test methodtwo new confined concrete columns with steel plate and horizontal strengthened bars and two cast-in-site columns with plain stirrups were designed and constructed. Through the pseudo-static test, the carrying capacity and seismic performance of the fabricated confined concrete column with steel plate and horizontal strengthened bar were studied and compared with the cast-in-site columns with plain stirrups. The whole process of deformingdamagingcrackingyieldingfailure was observed during the test. Damage characteristics, hysteretic curves, skeleton curves,stiffness degradation, displacement ductility and energy dissipation capacity of the four columns were discussed. The test results show that under the same condition, bearing capacity of the new fabricated confined concrete columns with steel plate and horizontal strengthened bar is equal to the cast-in-site columns with plain stirrups, and it also has good seismic performance. Junction of the new fabricated confined concrete columns with steel plate and horizontal strengthened bar used welding and horizontal bar as its attended mode is reliable.

Keywords: high-strength spiral stirrup; confined concrete; fabricated column; horizontal strengthened bar; seismic performance

*国家自然科学基金项目(10572107),河北省地方科技项目(2011188)。

作者简介:李青宁,教授,硕士,Email:lqn952@163.com

 

参考文献

1Precast and Prestressed Concrete Institute. PCI design handbookM. 1978.

2]薛伟辰.预制混凝土框架结构体系研究与应用进展[J.工业建筑,2002, 32(11):47-50.

3]史庆轩,侯炜,姜维山,.箍筋约束混凝土结构及其发展展望[J. 建筑结构学报,2009(S2)109-114.

4GB 500102010 混凝土结构设计规范[S. 北京:中国建筑工业出版社,2011.

5]李忠献,张雪松,丁阳.装配整体式型钢混凝土框架节点抗震性能研究[J. 建筑结构学报,2005(8):32-38.

下载地址

    你还没注册?或者没有登录?这篇论文要求至少是本站的注册会员才能阅读!

    如果你还没注册,请赶紧点此注册吧!

    如果你已经注册但还没登录,请赶紧点此登录吧!