对公共卫生间当量均布荷载的取值探讨
- 摘 要
-
(天脊煤化工集团股份有限公司, 潞城 047507)[摘要]按照公共卫生间蹲便器台阶、小便槽踏步的常用做法,计算出其荷载值,将其值减去防水楼面的荷载值,得出局部荷载;并将常见的三种布置类型的公共卫生间的局部荷载分别换算成三种当量均布荷载,因其值相差很少,故综合后取为1.50kN/m2,以便大家使用和参考。[关键词]公共卫生间; 蹲便器台阶; 小便槽踏步; 局部荷载; 当量荷载中图分类号:TU312 文献标识码:A 文章编号:1002-848X(2013)22-0065-03Discussion on the value of equivalent uniformly distributed load for public washroomXu Guoming(Tianji Coal Chemical Industry Group Co., Ltd., Lucheng 047507, China)Abstract: Load of public washroom is calculated according to the common practice of squatting span step and urinal troughs steps. Local load can be drawn through the above results subtractting the load of waterproof floor. Local loads of three common types of public washroom are converted into equivalent uniformly distributed load, which is set as 1.5kN/m2 for reference considering little deviations between three values.Keywords: public washroom; squatting span step; urinal troughs step; local load; equivalent load作者简介:徐国明,二级注册建筑师,二级注册结构工程师,注册监理工程师,Email:xgm-sxlc@163.com。参考文献[1]山西省建筑标准设计办公室. 05系列建筑标准设计图集[S].北京:中国建筑工业出版社,2005.[2]华北地区建筑设计标准化办公室,西北地区建筑标准设计协作办公室.88J建筑构造通用图集[S].[3]中国建筑标准设计研究院.05J909工程做法[S]. 北京:中国计划出版社,2006:91.[4]GB 50009—2012建筑结构荷载规范[S].北京:中国建筑工业出版社,2012.[5]建筑结构静力计算手册编写组.建筑结构静力计算手册[M].北京:中国建筑工业出版社,1978:146-147.[6]GB 50352—2005民用建筑设计通则[S].北京:中国建筑工业出版社,2005.